Enhance Your Home Comfort with Smart Lighting, Bedding Sets, Fans, and More!
Enhance Your Home Comfort with Smart Lighting, Bedding Sets, Fans, and More! Enhance Your Home Comfort with Smart Lighting, Bedding Sets, Fans, and More!
Home Ventilator Table Fan
Dell PowerEdge R760XS Rack Server Chassis (16x 2.5")

Dell PowerEdge R760XS Rack Server Chassis (16x 2.5")

$ 55.25

$ 71.83

Unavailable
Dell PowerEdge R760XS Rack Server Chassis (16x 2.5")

Dell PowerEdge R760XS Rack Server Chassis (16x 2.5")

$ 55.25

$ 71.83

Title:
  • DefaultTitle
Unavailable
Please select combo product attributes
The combo subtotal is $,SAVE$

Product Details

Quick Specs

Form Factor:

2U rack server

Processor | Max: 32 Cores

2x Gen 4 Intel Xeon Scalable

Memory | Max: 1TB

16 ECC DDR5 RDIMM 4800Mhz

Storage | Max: 244.48TB

Front bays:
Up to 16 x 2.5" SAS/SATA (HDD/SSD) Max: 121.6 TB
Rear bays:
Not Supported

Boot Options

Boot Optimized Server Storage (BOSS-N1) Hot-Swap
USB

RAID Controller: (Adapter PERC)

S160 (SATA/NVMe SW RAID)
H355, H755, H755N, H965i, HBA355i, HBA355e, H965e

LOM

2 x 1GbE LOM card with BCM5720 LAN controller

Networking Options | Max Speed: 4x 25GbE Ports

OCP 3.0 x8 Mezz 3.0

Remote Management:

iDRAC9 with Lifecycle Controller

PCIe Slots:

1 CPU Config: Up to 4 PCIe slots (2 x8 Gen5, 1 x16 Gen4, 1 x8 Gen4)
2 CPU config: Up to 6 PCIe slots (2 x16 Gen5, 3 x16 Gen4, 1 x8 Gen4)

GPU:

2 x 75 W SW, LP

Other Versions:

Ideal for:

  • Database
  • Virtual Desktop Interface (VDI)
  • Virtualization
  • Virtual Machines (VM)
Buy the performance and flexibility you need

The new Dell PowerEdge R760xs is a 2U, two-socket rack server. Buy the best fit in scalable performance and large storage capability with this purpose-built 2U system. Focused on delivering the latest technology to power the most popular applications and workloads used by businesses today, including virtual desktop infrastructure (VDI), virtual machines (VMs), and software-defined storage (SDS). All delivered in a thoughtfully crafted platform that will provide balanced compute that fits in your current infrastructure.


Easily configurable

Maximize your workload performance and boost outcomes with scale as you grow to compute, flexibly supporting a wide range of GPUs in a dual-socket/2U air-cooled server, accelerating applications from AI training and inferencing to Digital Twins to performance graphics and dense power-user collaboration environments.

  • Add up to two 4th generation Intel® Xeon® Scalable processors with up to 32 cores per socket for faster performance
  • Accelerate in-memory workloads with up to 16 DDR5 RDIMMS up to 4800 MT/sec
  • Improve data throughput and reduce latency with support up to 8 I/O device (up to available 6 PCIe slots, 1 OCP 3.0 networking slot, and 1 dedicated PERC slot)
  • Storage options include up to 12x 3.5” HDDs/SSDs, or up to 16x 2.5” HDD/SSDs, plus up to 8x NVMe drives

A breeze to cool

The 6 hot swappable fans come in 3 different types. Standard (STD) fans or the High performance Silver (HPR) fans or the High performance Gold (VHP) fans. Most configurations have the Standard Fan kit, If you install the BOSS-N1, GPU, or Rear Drives, Fan 1 will be upgraded to a GOLD fan. Below is a table outlining each config.

  • Thoughtfully designed to fit in your current air-cooled infrastructure
  • Alleviate the worry about expensive liquid cooling retrofitting to your data center
  • Synchronize your workload needs with a tailored performance configuration that is air cooled
  • Minimize the carbon footprint of your data center by better matching the system power consumption with anticipated workload requirements

Increase efficiency and accelerate operations with autonomous collaboration

The Dell OpenManage™ systems management portfolio delivers a secure, efficient, and comprehensive solution for PowerEdge servers. Simplify, automate and centralize one-to-many management with the OpenManage Enterprise console and iDRAC.

Cyber Resilient Architecture for Zero Trust IT environment & operations

Security is integrated into every phase of the PowerEdge lifecycle, including protected supply chain and factory-to-site integrity assurance. Silicon-based root of trust anchors end-to-end boot resilience while Multi-Factor Authentication (MFA) and role-based access controls ensure trusted operations


Dell PowerEdge R760XS Base Knowledge

Strike the right balance between performance and flexibility with this air-cooled solution designed for the most popular IT applications.

  • Add up to two 4th generation Intel® Xeon® Scalable processors with up to 32 cores per socket for faster performance
  • Accelerate in-memory workloads with up to 16 DDR5 RDIMMS up to 4800 MT/sec
  • Improve data throughput and reduce latency with support up to 8 I/O devices
  • Up to 6 PCIe slots, 1 OCP 3.0 networking slot, and 1 dedicated PERC slot
  • Storage options include up to 12 x 3.5” HDDs/SSDs; or up to 16 x 2.5” HDD/SSDs, plus up to 8 x NVMe drives
Dell PowerEdge R760xs Configuration Options
Front Bay Drive Options:

All models support the BOSS option, with the exception of the 12 Bay Chassis. All other options support up to 2 GPUs if both CPUs are installed. The 12 Bay is the only config to support the rear bay option.

Drives Configurations:
  • 0 drive bay
  • 8x 3.5" SAS/SATA
  • 12x 3.5" SAS/SATA 2x 2.5" SAS/SATA/NVMe
  • 8x 2.5" SAS/SATA
  • 8x 2.5" NVMe
  • 16x 2.5" SAS/SATA
  • 16x 2.5" SAS/SATA 8x 2.5" NVMe

Rear Bay Drive Options:

Only Supported on the 12 Bay Chassis. The rear-drive module doesn't support Kioxia CM6 series, Samsung PM1735 series, Hynix PE8010 7.68TB, Samsung PM1733a > 1.92TB, Samsung PM1735a > 1.6TB and Redtail NVMe drive.

Drives Supported in Rear
  • SAS (HDD/SSD)
  • SATA (HDD/SSD)
  • NVME (SSD)
  • Max Drive Capacity: 30.72TB

NOTE:

The 16 x 2.5-inch SAS/SATA backplane configuration is a combination of two 8 x 2.5-inch SAS/SATA backplanes, in 16 x 2.5-inch SAS/SATA 8 x 2.5-inch NVMe backplane configuration and 16 x 2.5-inch SAS/SATA configuration in PowerEdge R760xs.


Limitations with the 12 LFF Chassis

The 12 Bay Chassis has some major restrictions with Thermal and what gear can be installed.

  • Cannot support PCIe card with the cooling requirement of more than 300LFM at 55C.
  • Cannot support OCP card with a cooling requirement of more than 250LFM at 55C
    (3Y64D / 4TRD3 / GGGDF / R1KTR / Y4VV5) .
  • Solarflare Melrose DP 25 GBE SFP28 (TTKWY) not supported.
  • 100 Gb network adapter or 100 Gb OCP is not supported.
  • The 12 Bay Chassis requires the optical transceiver with higher temperature spec (≥ 85°C) to support (M14MK / N8TDR).
  • The 12 Bay Chassis is the only one to support the rear drive cage.
Processor

The following lists the features and functions that are in the upcoming 4th Generation Intel® Xeon Scalable Processor offering:

  • Faster UPI with up to four Intel Ultra Path Interconnect (Intel UPI) at up to 16 GT/s, increasing multi-socket bandwidth.
  • More, faster I/O with PCI Express 5 and up to 80 lanes (per socket)
  • Enhanced Memory Performance with DDR5 support and memory speed up to 4800 MT/s in one DIMM per channel (1DPC) and 4400 MT/s in two DIMM per channel (2DPC)
  • New built-in accelerators for data analytics, networking, storage, crypto, and data compression
Heatsink & Fans

The Dell R760XS Rack Server has 2 Heatsinks options that will change based on the TDP of the Processors. The Dell R760xs also has 3 different types of Fans; Standard, Silver, and Gold Fans. These fans will be changed based on other components installed. Below is a table outlining those changes.


Heatsink (HSK) TDP Rules

If the processor's TDP is below 185W an STD HSK will be installed otherwise the Highperformance HSK will be installed.
Except the 12 Bay Chassis with a Processor that has a TDP below 125W supports the Standard Heatsink.


Fan Config Rules

Optional fan zone 1 has to be populated with HPR Gold fan for BOSS, GPU, or rear drive module populations. A fan blank is required on fan zone 1 when no fan is populated


Fan population rule for Dell PowerEdge R760xs
Configuration No backplane 8x 3.5" SAS 12x 3.5" SAS 8x 2.5" SAS 8x 2.5" NVMe 16x 2.5" SAS 24x 2.5" (16x 2.5" 8x 2.5" NVMe)
Default Fan 2 to Fan 6 with STD fan Fan 2 to Fan 6 with STD fan Fan 2 to Fan 6 with HPR Silver fan Fan 2 to Fan 6 with STD fan Fan 2 to Fan 6 with HPR Silver fan Fan 2 to Fan 6 with STD fan Fan 2 to Fan 6 with HPR Silver fan
Rear Module Not Supported Not Supported Fan 2 to Fan 6 with HPR Silver fan Not Supported Not Supported Not Supported Not Supported
BOSS-N1 Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan Fan 1 with HPR Gold fan Fan 2 to Fan 6 with STD fan Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan
GPU Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan Not Supported Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan Fan 1 with HPR Gold fan Fan 2 to Fan 6 with HPR Silver fan
Memory

The Dell R760XS Rack Server on a two-socket configuration supports 16 DDR5 DIMM slots. Up to 1TB of RDIMM with speeds up to 4800 MT/s and supports registered ECC DDR5 DIMMs only.

  • All DIMMs must be DDR5
  • Memory mixing is not supported for different DIMM capacities.
  • A minimum of 1 DIMM must be populated for each installed processor.
DIMM type Rank Capacity Single processor Dual processors DIMM rated voltage and speed Operating Speed
Minimum memory capacity Maximum memory capacity Minimum memory capacity Maximum memory capacity 1 DIMM per channel (DPC)
RDIMM Single Rank 16 GB 16 GB 128 GB 32 GB 256 GB DDR5 (1.1 V), 4800 MT/s 4800 MT/s
Dual Rank 32 GB 32 GB 256 GB 64 GB 512 GB DDR5 (1.1 V), 4800 MT/s 4800 MT/s
64 GB 64 GB 512 GB 128 GB 1 TB DDR5 (1.1 V), 4800 MT/s 4800 MT/s
Networking Adapters

The LOM and OCP are great ways to expand the networkability of the server. The LOM is built into the system board and supports 2x 1GbE ports. While the Optional OCP 3.0 supports 4 ports up to speeds of 25Gb/s. If the OCP card is installed without the rear riser, The OCP air shroud must be installed.

These networking slots don’t take up a PCIe lane which allows you more flexibility and freedom to configure your server how you see fit. If you have any concerns about the right card for your build. Please reach out to us via email or chat.


LOM Ports:

1 GB x 2

OCP Ports:

1 GbE x 4, 10 GbE x 2, 10 GbE x 4, 25 GbE x 2, 25 GbE x 4

Expansion Slots

This system can support Single or Dual processors configurations. Based on the Socket configuration the sytem can hold from 2 LP Gen 4 slots. Up to 6 PCIe slots rangeing from x8 Gen4 to x16 Gen5. Only one cable riser can be installed at a time in any given configuration.
Slots 1, 2, 5, and 6 are Gen4 slots, slots 3 and 4 located on risers are Gen5 slots.

Configurations Expansion card risers PCIe Slots Controlling processor Height Length Slot width Power
Config 0-1. No riser 1, 2 Processor 1 Low profile Half length x16, x8 75 W
Config 0-2. No riser 1, 2 Processor 1 Low profile Half length x16, x8 75 W
No riser 5, 6 Processor 2 Low profile Half length x16, x16 75 W
Config 1. R1C 1, 2, 3 Processor 1 Low profile Half length x16, x8, x16 75 W
4, 5, 6 Processor 2 Low profile Half length x16, x16, x16 75 W
Config 2. R1D 1, 2, 3, 4 Processor 1 Low profile Half length x16, x8, x8, x8 75 W
Storage Controllers

NOTE: The Adapter PERC is only available with 12 x 3.5-inch SAS/SATA backplane configuration. All the other Chassis will have an fPERC , Rear Mounted installed for RAID and SAS control.

Performance Level Controller and Description
Software NA (No SW RAID)
Internal H355, H755, H965i
External H965e,
SAS Host Bust Adapters (HBA) HBA355i, HBA355e
Storage Controller Specs
Model & Form Factors Interface Support PCI Support SAS Connection Cache Memory Size Write Back Cache RAID Levels Max Drive Support RAID Support
PowerEdge Server-Storage Controllers (PERC) Series 12
H965i Front 24Gb/s SAS
6Gb/s SAS/SATA
Gen3 (8 GT/s) NVMe
Gen4 (16 GT/s) NVMe
PCIe Gen 4 16 ports/lanes - 2x8 Internal 8GB NV Flash Backed Cache 0,1,5,6,10,50,60 16 Hardware
H965i Adapter 24Gb/s SAS
6Gb/s SAS/SATA
Gen3 (8 GT/s) NVMe
Gen4 (16 GT/s) NVMe
PCIe Gen 4 16 ports/lanes - 2x8 Internal 8GB NV Flash Backed Cache 0,1,5,6,10,50,60 16 Hardware
S160 Software RAID Gen4 (16 GT/s) NVMe PCIe Gen 4 N/A No Cache No Cache 0,1,5,10 8 Software RAID - Windows Only
PowerEdge Server-Storage Controllers (PERC & SAS HBA) Series 11
H755 Adapter 12Gb/s SAS
6Gb/s SAS/SATA
3Gb/s SAS/SATA
Gen3 (8 GT/s) NVMe
Gen4 (16 GT/s) NVMe
PCIe Gen 4 16 ports- 2x8 Internal 8GB NV Flash Backed Cache 0,1,5,6,10,50,60 16 Per Controller / 50 with SAS Expander Hardware
H755N Front
(NVMe Only)
Gen3 (8 GT/s) NVMe Gen4 (16 GT/s) NVMe PCIe Gen 4 16 ports- 2x8 Internal 8GB NV Flash Backed Cache 0,1,5,6,10,50,60 8 Per Controller Hardware
H755 Front
(SAS/SATA only)
12Gb/s SAS
6Gb/s SAS/SATA
3Gb/s SAS/SATA
PCIe Gen 4 16 ports- 2x8 Internal 8GB NV Flash Backed Cache 0,1,5,6,10,50,60 16 Per Controller / 50 with SAS Expander Hardware
HBA355i Adapter 12Gb/s SAS
6Gb/s SAS/SATA
3Gb/s SAS/SATA
PCIe Gen 4 16 ports- 2x8 Internal N/A N/A N/A 16 Per Controller / 50 with SAS Expander N/A
HBA355i Front 12Gb/s SAS
6Gb/s SAS/SATA
3Gb/s SAS/SATA
PCIe Gen 4 16 ports- 2x8 Internal N/A N/A N/A 16 Per Controller / 50 with SAS Expander N/A
HBA355e Adapter 12Gb/s SAS
6Gb/s SAS/SATA
3Gb/s SAS/SATA
PCIe Gen 4 16 ports- 4x4 external N/A N/A N/A 240 N/A
H355 Adapter 12Gb/s SAS
6Gb/s SAS/SATA
PCIe Gen 4 16 ports- 2x8 Internal No Cache No Cache 0,1, 10 Up to 32 RAID,
or 32 Non- RAID
Hardware
H355 Front 12Gb/s SAS
6Gb/s SAS/SATA
PCIe Gen 4 16 ports- 2x8 Internal No Cache No Cache 0,1, 10 Up to 32 RAID,
or 32 Non- RAID
Hardware
Power, Dimensions & Weight:
Power:

Up to 2 60MM Hot-swap Redundant Power Supplies

  • 1800 W Titanium 200—240 VAC or 240 HVDC
  • 1400 W Platinum 100—240 VAC or 240 HVDC
  • 1100 W Titanium 100—240 VAC or 240 HVDC
  • 1100 W LVDC -48 — (-60) VDC
  • 800 W Platinum 100—240 VAC or 240 HVDC
  • 700 W Titanium 200—240 VAC or 240 HVDC
  • 600 W Platinum 100—240 VAC or 240 HVDC
Dimensions & Weight:

Width: 482 mm (18.97 inches)
Height: 86.8 mm (3.41 inches)
Length: 707.78 mm (27.85 inches) – without bezel
Length: 721.62 mm (28.4 inches) – with bezel
Weight Per Chassis:
16 8 x 2.5-inch - 25.92 kg (57.14 lb)
16 x 2.5-inch - 24.58 kg (54.18 lb)
12 x 3.5-inch - 28.82 kg (63.53 lb)
8 x 3.5-inch - 25.84 kg (54.96 lb)
8 x 2.5-inch - 21.56 kg (47.53 lb)
No backplane configuration - 19.40 kg (42.76 lb)

You May Also Like

Cart
Enhance Your Home Comfort with Smart Lighting, Bedding Sets, Fans, and More!
Your cart is currently empty.